Bug 505008 - Pager drag'n'drop picks window with a lower z-index
Summary: Pager drag'n'drop picks window with a lower z-index
Status: RESOLVED DUPLICATE of bug 497506
Alias: None
Product: plasmashell
Classification: Plasma
Component: Pager widget (other bugs)
Version First Reported In: 6.3.0
Platform: Other Linux
: NOR normal
Target Milestone: 1.0
Assignee: Plasma Bugs List
URL:
Keywords:
Depends on:
Blocks:
 
Reported: 2025-05-30 11:43 UTC by Alexander Potashev
Modified: 2025-06-13 20:42 UTC (History)
2 users (show)

See Also:
Latest Commit:
Version Fixed/Implemented In:
Sentry Crash Report:


Attachments

Note You need to log in before you can comment on or make changes to this bug.
Description Alexander Potashev 2025-05-30 11:43:41 UTC
SUMMARY
Pager drag'n'drop picks window with a lower z-index.

STEPS TO REPRODUCE
1. Configure at least 2 virtual desktops. (I also have use 2 monitors, but that should be unimportant.)
2. Start KWrite (or any other app)
3. Start SystemSettings (or any other different app).
4. Make sure the positions of these 2 windows have a significant overlap.
5. Focus the KWrite window, e.g. by clicking in it.
6. In Pager widget, click inside the intersection of both windows' outlines and drag to the other virtual desktop.

OBSERVED RESULT
SystemSettings window moved to the other virtual desktop.

EXPECTED RESULT
KWrite window should be moved to the other virtual desktop because it was focused and was on top (i.e. above the SystemSettings window).

SOFTWARE/OS VERSIONS
Operating System: gLinux Rodete
KDE Plasma Version: 6.3.0
KDE Frameworks Version: 6.11.0
Qt Version: 6.7.2
Kernel Version: 6.12.20-1rodete1-amd64 (64-bit)
Graphics Platform: Wayland
Processors: 12 × Intel® Xeon® W-2135 CPU @ 3.70GHz
Memory: 62.4 GiB of RAM
Graphics Processor: Quadro P1000/PCIe/SSE2

ADDITIONAL INFORMATION
Comment 1 John Kizer 2025-06-13 20:42:19 UTC
Merging this in with the existing report for this issue - this was fixed in Plasma 6.3.1.

*** This bug has been marked as a duplicate of bug 497506 ***