Summary When FlipFlat is selected in the Optical Train for both dust cap and light panel, any attempt to generate a flat hangs KStars immediately after the "Turn light box light on..." status message. Happens both while running a sequence job or attempting a manual preview. The progress indicator in the lower right of the Capture Module says "Preparing..." I get the "force quit" dialog from Ubuntu after a short time. Curiously, the log warns about "Always Reset Sequence" enabled, but it is not enabled. I have a FlipFlat and have the optical train set correctly. If I remove the FlipFlat from the optical train config and close the cover and turn on the light manually, the sequence runs fine. Log Excerpt: [2023-12-08T08:22:21.589 CST INFO ][ org.kde.kstars.ekos.capture] - "Warning: option \"Always Reset Sequence When Starting\" is enabled and resets the sequence counts." [2023-12-08T08:22:21.590 CST INFO ][ org.kde.kstars.ekos.capture] - "Job requires 2.000-second Ha images, has 0/20 frames captured and will be processed." [2023-12-08T08:22:21.592 CST INFO ][ org.kde.kstars.ekos.capture] - "Parking dust cap..." [2023-12-08T08:22:21.593 CST INFO ][ org.kde.kstars.ekos.capture] - "Warning: temperature delta check is selected but autofocus process was not started." [2023-12-08T08:22:22.767 CST INFO ][ org.kde.kstars.indi] - Flip Flat : "[INFO] Cover closed. " [2023-12-08T08:22:22.767 CST INFO ][ org.kde.kstars.ekos.capture] - "Dust cap parked." [2023-12-08T08:22:22.768 CST INFO ][ org.kde.kstars.ekos.capture] - "Light box on." [2023-12-08T08:22:22.769 CST INFO ][ org.kde.kstars.ekos.capture] - "Turn light box light on..."
Cannot reproduce in KStars 3.6.8
Should be fixed in 3.7.1