Conditions: Running a capture sequence that includes flat or dark images with an automated cap / light panel. I use a FlipFlat. Issue: When capturing an image sequence that includes flats with an INDI light cap connected, the guider (PHD2) will start it's fail logic because it can't guide anymore. Request: The Focus Module pauses guiding when it performs it's tasking. The Capture Module should do the same when it's generating flat or dark images (cap/light closed).
I should mention that the guider in this scenario is an OAG - which is why PHD2 complains.
Git commit 25230b5971feafb0c271d4a0ea6f6d21290c5386 by Jasem Mutlaq. Committed on 20/12/2023 at 11:26. Pushed by mutlaqja into branch 'master'. Fix guiding suspend not working properly when capturing non-light frames. FIXED-IN:3.6.8 M +2 -1 kstars/ekos/capture/captureprocess.cpp https://invent.kde.org/education/kstars/-/commit/25230b5971feafb0c271d4a0ea6f6d21290c5386
Git commit d15e5d001c8996294e8f5109deca02f262fe1016 by Jasem Mutlaq. Committed on 20/12/2023 at 12:06. Pushed by mutlaqja into branch 'stable-3.6.8'. Fix guiding suspend not working properly when capturing non-light frames. FIXED-IN:3.6.8 M +2 -1 kstars/ekos/capture/captureprocess.cpp https://invent.kde.org/education/kstars/-/commit/d15e5d001c8996294e8f5109deca02f262fe1016