Bug 448485 - kscreen fails to set display scale twice in sequence
Summary: kscreen fails to set display scale twice in sequence
Status: RESOLVED FIXED
Alias: None
Product: systemsettings
Classification: Applications
Component: kcm_kscreen (other bugs)
Version First Reported In: 5.23.90
Platform: Arch Linux Linux
: NOR normal
Target Milestone: ---
Assignee: kscreen-bugs-null@kde.org
URL:
Keywords:
Depends on:
Blocks:
 
Reported: 2022-01-14 18:02 UTC by Patrick Silva
Modified: 2022-06-14 15:48 UTC (History)
3 users (show)

See Also:
Latest Commit:
Version Fixed/Implemented In:
Sentry Crash Report:


Attachments

Note You need to log in before you can comment on or make changes to this bug.
Description Patrick Silva 2022-01-14 18:02:07 UTC
STEPS TO REPRODUCE
1. open Display Configuration KCM
2. use the slider to change display scale from 100% to 125%
3. click on 'Apply' button (dialog to keep/revert the change shows up, click on 'Keep' button)
4. use the slider to change display scale from 125% to 100%
5. click on 'Apply' button (display scale 100% is applied to my screen but no dialog shows up this time)

OBSERVED RESULT
display scale is reverted to 125% 15 seconds after the last step and the KCM displays "Display configuration reverted." inline message.

EXPECTED RESULT
changes done in Display Configuration KCM should always be correctly applied

SOFTWARE/OS VERSIONS
Operating System: Arch Linux
KDE Plasma Version: 5.23.90
KDE Frameworks Version: 5.90.0
Qt Version: 5.15.2
Graphics Platform: Wayland
Comment 1 Méven Car 2022-02-15 10:07:09 UTC
Related to https://bugs.kde.org/show_bug.cgi?id=442743
Comment 2 Patrick Silva 2022-06-14 15:48:00 UTC
Cannot reproduce.

Operating System: Arch Linux
KDE Plasma Version: 5.25.0
KDE Frameworks Version: 5.95.0
Qt Version: 5.15.4
Graphics Platform: Wayland