STEPS TO REPRODUCE 1. right-click on plasma panel 2. choose "Edit panel..." 3. OBSERVED RESULT "panel height" field is not focused. EXPECTED RESULT "panel height" field should be focused and the current value selected, so we can immediately start to type another value. SOFTWARE/OS VERSIONS Operating System: KDE neon Unstable Edition KDE Plasma Version: 5.19.80 KDE Frameworks Version: 5.72.0 Qt Version: 5.14.2
Not a bad idea.
A possibly relevant merge request was started @ https://invent.kde.org/plasma/plasma-desktop/-/merge_requests/56
Git commit 5837d769fa28a2f87ea021ddc55da9c111523a2b by Nate Graham. Committed on 15/07/2020 at 04:33. Pushed by ngraham into branch 'master'. [Panel toolbox] Focus Panel thickness spinbox by default Seems like a sensible enough thing to focus by default, and additionally right now nothing is focused by default so it's unclear where the keyboard focus begins. FIXED-IN: 5.20 M +1 -0 desktoppackage/contents/configuration/panelconfiguration/ToolBar.qml https://invent.kde.org/plasma/plasma-desktop/commit/5837d769fa28a2f87ea021ddc55da9c111523a2b