I am trying the Plasma 5.9 Beta with Wayland and it works really good so far, you did a really good job, thank you! I am very much looking forward to change to it by default for daily use and therefore test it a lot. Until now, I noticed only one major bug on my setup: I have two monitors and the "DELL" monitor should be the primary and the other ("ViewSonic VP2250wb") shoud be _left_ of it. I configured it that way on X11 some day (or it was the default) and it is working perfectly there. When starting a Plasma Wayland session, the arrangement is inversed, i.e. Plasma expects the secondary monitor on the _right_ of "DELL". (See attached screenshot). When I correct the positioning in systemsettings (see 2nd screenshot) and apply the change, the positioning is changed but the mouse cursor is trepped on the secondary ("VP2250wb", now left) screen.
Created attachment 103406 [details] The initial monitor layout after starting Plasma Wayland session
Created attachment 103407 [details] The desired monitor layout
Created attachment 103408 [details] The output of "kscreen-console bug"
I am using Qt 5.7.1. Please let me know if you need more information, if I should perform more tests and/or apply patches.
Thanks for the bugreport! Unfortunately, I don't have a patch ready to fix the behavior right now, but we'll keep it in mind!
Still happening with recent Plasma 5.10.0
(In reply to Fabian Köster from comment #6) > Still happening with recent Plasma 5.10.0 Can you still reproduce this issue?
> Can you still reproduce this issue? I am not using Plasma at the moment so I cannot tell if this issue still exists, sorry. Because apparently no one else observed this issue, I am closing this ticket.