Bug 375033 - Wayland multiscreen: When changing positioning of monitors, mouse cursor is trapped on one screen
Summary: Wayland multiscreen: When changing positioning of monitors, mouse cursor is t...
Status: RESOLVED FIXED
Alias: None
Product: KScreen
Classification: Plasma
Component: common (show other bugs)
Version: 5.10.0
Platform: Gentoo Packages Linux
: NOR normal
Target Milestone: ---
Assignee: Sebastian Kügler
URL:
Keywords:
Depends on:
Blocks:
 
Reported: 2017-01-14 10:18 UTC by Fabian Köster
Modified: 2018-07-16 09:01 UTC (History)
1 user (show)

See Also:
Latest Commit:
Version Fixed In:
Sentry Crash Report:


Attachments
The initial monitor layout after starting Plasma Wayland session (63.85 KB, image/png)
2017-01-14 10:20 UTC, Fabian Köster
Details
The desired monitor layout (63.25 KB, image/png)
2017-01-14 10:21 UTC, Fabian Köster
Details
The output of "kscreen-console bug" (4.20 KB, text/plain)
2017-01-14 10:22 UTC, Fabian Köster
Details

Note You need to log in before you can comment on or make changes to this bug.
Description Fabian Köster 2017-01-14 10:18:49 UTC
I am trying the Plasma 5.9 Beta with Wayland and it works really good so far, you did a really good job, thank you!

I am very much looking forward to change to it by default for daily use and therefore test it a lot. 

Until now, I noticed only one major bug on my setup: I have two monitors and the "DELL" monitor should be the primary and the other ("ViewSonic VP2250wb") shoud be _left_ of it. I configured it that way on X11 some day (or it was the default) and it is working perfectly there. When starting a Plasma Wayland session, the arrangement is inversed, i.e. Plasma expects the secondary monitor on the _right_ of "DELL". (See attached screenshot).

When I correct the positioning in systemsettings (see 2nd screenshot) and apply the change, the positioning is changed but the mouse cursor is trepped on the secondary ("VP2250wb", now left) screen.
Comment 1 Fabian Köster 2017-01-14 10:20:36 UTC
Created attachment 103406 [details]
The initial monitor layout after starting Plasma Wayland session
Comment 2 Fabian Köster 2017-01-14 10:21:40 UTC
Created attachment 103407 [details]
The desired monitor layout
Comment 3 Fabian Köster 2017-01-14 10:22:32 UTC
Created attachment 103408 [details]
The output of "kscreen-console bug"
Comment 4 Fabian Köster 2017-01-14 10:23:27 UTC
I am using Qt 5.7.1. Please let me know if you need more information, if I should perform more tests and/or apply patches.
Comment 5 Sebastian Kügler 2017-01-23 09:16:23 UTC
Thanks for the bugreport! Unfortunately, I don't have a patch ready to fix the behavior right now, but we'll keep it in mind!
Comment 6 Fabian Köster 2017-06-06 05:37:04 UTC
Still happening with recent Plasma 5.10.0
Comment 7 Alexander Mentyu 2018-07-14 07:32:12 UTC
(In reply to Fabian Köster from comment #6)
> Still happening with recent Plasma 5.10.0

Can you still reproduce this issue?
Comment 8 Fabian Köster 2018-07-16 09:01:07 UTC
> Can you still reproduce this issue?

I am not using Plasma at the moment so I cannot tell if this issue still exists, sorry.