Description gerben.jansen 2016-02-07 10:01:34 UTC
When ksysguard connects to a remote machine (after i entered the wallet password), the sensor is displayed, but the scales in the plot are not set properly.
If i then exit ksysguard and restart it, it again asks for the wallet password, but then the scales are correct

Reproducible: Always

Steps to Reproduce:
1. Make you remote machine unreachable
2. Start ksysguard on the remote machine
3. Exit ksysguard
4. Make the remote machine reachable again
5. Start ksysguard
6. Enter the wallet password
7. Now the scales are incorrect
8. Stop and start ksysguard one more time
9, Now the scales are correct.

Actual Results:  
Sensor is display with incorrect scales

Expected Results:  
Sensors are display with correct scales

I'm running on openSUSE Lead 42.1
Comment 1 gerben.jansen 2016-04-01 08:53:33 UTC
Any news ?
Comment 2 Richard Llom 2019-03-11 16:19:11 UTC
Can you reproduce this issue with current version of ksysguard and qt?
Comment 3 gerben.jansen 2019-03-12 10:47:39 UTC
I'm currently running Leap 15.0 on both nodes and the issue changed a little, but i am still able to reproduce the scaling issue.

1. i run ksysguard on the local node L and monitor remote node R
2. the scales are correct
3. while ksysguard is running i shutdown node R
4. ksysguard stops displaying the remote sensors (of course)
5. I stop running ksysguard
6. next i start node R again
7. once node R is up completely i start running ksysgard again on node L to monitor node R
8. Now the scales are wrong and the sensor isn't displayed (not sure this is equal to the original issue)
9. Only when i select File -> Monitor Remote Machine -> Enter R, the sensors will start displaying again, but the scale is still incorrect.
10. Only stopping ksysguard and starting it again, will fix the scaling as well.

When i stop ksysguard first instead of step 3 and start it again after node R is up and running, ksysgard works OK (so that's the procedure i normally follow to work around this)

On node L:
$ rpm -qa | grep ksys
ksysguard5-lang-5.12.6-lp150.2.3.1.noarch
libksysguard5-helper-5.12.6-lp150.2.3.1.x86_64
ksysguard5-5.12.6-lp150.2.3.1.x86_64
libksysguard5-5.12.6-lp150.2.3.1.x86_64
libksysguard5-lang-5.12.6-lp150.2.3.1.noarch

On node R:
rpm -qa|grep ksys
libksysguard5-lang-5.12.6-lp150.2.3.1.noarch
ksysguard5-5.12.6-lp150.2.3.1.x86_64
ksysguard5-lang-5.12.6-lp150.2.3.1.noarch
libksysguard5-5.12.6-lp150.2.3.1.x86_64
libksysguard5-helper-5.12.6-lp150.2.3.1.x86_64
Comment 4 Bug Janitor Service 2019-03-27 04:33:15 UTC
Dear Bug Submitter,

This bug has been in NEEDSINFO status with no change for at least
15 days. Please provide the requested information as soon as
possible and set the bug status as REPORTED. Due to regular bug
tracker maintenance, if the bug is still in NEEDSINFO status with
no change in 30 days the bug will be closed as RESOLVED > WORKSFORME
due to lack of needed information.

For more information about our bug triaging procedures please read the
wiki located here:
https://community.kde.org/Guidelines_and_HOWTOs/Bug_triaging

If you have already provided the requested information, please
mark the bug as REPORTED so that the KDE team knows that the bug is
ready to be confirmed.

Thank you for helping us make KDE software even better for everyone!
Comment 5 Christoph Feck 2019-03-27 07:42:40 UTC
New Information was added with comment #3; changing status for inspection.
Comment 6 Christoph Cullmann 2024-09-23 21:00:09 UTC
ksysguard is no longer maintained, in Plasma 6 there is the Plasma system monitor for this task.