Bug 356728 - Incorrect width of the confirmation screen when rebooting
Summary: Incorrect width of the confirmation screen when rebooting
Status: RESOLVED WORKSFORME
Alias: None
Product: ksmserver
Classification: Unmaintained
Component: ui (show other bugs)
Version: 5.5.0
Platform: Arch Linux Linux
: NOR minor
Target Milestone: ---
Assignee: Lubos Lunak
URL:
Keywords:
Depends on:
Blocks:
 
Reported: 2015-12-15 11:04 UTC by Viorel-Cătălin Răpițeanu
Modified: 2019-02-08 16:13 UTC (History)
3 users (show)

See Also:
Latest Commit:
Version Fixed In:
Sentry Crash Report:


Attachments
The confirmation page when logout was selected from the 1920x1080 monitor. (3.54 MB, image/png)
2015-12-15 11:13 UTC, Viorel-Cătălin Răpițeanu
Details
Confirmation screen when logout was selected from the 1920x1080 monitor. (3.51 MB, image/png)
2015-12-15 11:18 UTC, Viorel-Cătălin Răpițeanu
Details

Note You need to log in before you can comment on or make changes to this bug.
Description Viorel-Cătălin Răpițeanu 2015-12-15 11:04:14 UTC
The width of the logout/restart/poweroff confirmation screen depends on the resolution of the monitor from which it was selected. However, the notification is always being displayed on the primary screen.

If you have 2 displays with different resolutions eg: 1600x900 and 1920x1080, and you select the 1920x1080 monitor as being your primary, the width of your confirmation displayed on your primary monitor will will depend on the resolution of the monitor from which the action was activated. Doing this from the smaller display, the confirmation screen will spawn only 900 pixels from the 1080 available on the primary display. See attached pictures.

Reproducible: Always

Steps to Reproduce:
1. Have two displays of different resolutions connected. (Ex: 1600x900 and 1920x1080)
2. Set the display with a bigger resolution as your primary output.
3. Try to logoff from an action menu. 
4. Do step 3 from a menu that is located on each monitor.

Actual Results:  
The confirmation screen is appearing on the primary output with the width of the monitor from which the action was selected.

Expected Results:  
1. The confirmation should appear on your primary output stretching the whole width, no matter the place from which the action was selected.
2. The confirmation should appear on the monitor from which the action was selected, keeping the width of that respective monitor
3. The confirmation should appear on all connected monitors, each having the size of their respective monitor.

See attachments displaying both scenarios.
Comment 1 Viorel-Cătălin Răpițeanu 2015-12-15 11:13:10 UTC
Created attachment 96084 [details]
The confirmation page when logout was selected from the 1920x1080 monitor.
Comment 2 Viorel-Cătălin Răpițeanu 2015-12-15 11:15:59 UTC
The previous attachement is when logout was selected from the 1600x900 monitor. I renamed the wrong document.
Comment 3 Viorel-Cătălin Răpițeanu 2015-12-15 11:18:15 UTC
Created attachment 96085 [details]
Confirmation screen when logout was selected from the 1920x1080 monitor.

The previous attachment 96084 [details] is for the situation when logout was selected from the smaller monitor (1600x900).
Comment 4 Viorel-Cătălin Răpițeanu 2019-01-18 12:53:01 UTC
Since the confirmation screen was changed in the recent Plasma releases, this ticket is no longer applicable. As a result, I suggest to close it as no longer applicable.
Comment 5 Christoph Feck 2019-02-08 16:13:22 UTC
Thanks for the update; changing status. If you see this issue again, please add a comment.