Bug 176268 - systemmonitor temperature plasmoid: display distorted
Summary: systemmonitor temperature plasmoid: display distorted
Status: RESOLVED FIXED
Alias: None
Product: plasma4
Classification: Unmaintained
Component: general (show other bugs)
Version: unspecified
Platform: Compiled Sources Linux
: NOR normal
Target Milestone: ---
Assignee: Plasma Bugs List
URL:
Keywords:
Depends on:
Blocks:
 
Reported: 2008-11-27 21:25 UTC by Alexander Rössler
Modified: 2008-12-18 07:47 UTC (History)
1 user (show)

See Also:
Latest Commit:
Version Fixed In:
Sentry Crash Report:


Attachments
SystemMonitor - Temperature default size (8.74 KB, image/jpeg)
2008-12-12 20:07 UTC, Dario Andres
Details

Note You need to log in before you can comment on or make changes to this bug.
Description Alexander Rössler 2008-11-27 21:25:17 UTC
Version:           4.1.80 (using Devel)
OS:                Linux
Installed from:    Compiled sources

When you add the temperature monitor plasmoid to the desktop, the analog display is distorted. To resolve this I have to resize the plasmoid.
Comment 1 Dario Andres 2008-12-12 20:07:17 UTC
Created attachment 29278 [details]
SystemMonitor - Temperature default size

I can confirm this bug using:
Qt: 4.4.3
KDE: 4.1.85 (KDE 4.1.85 (KDE 4.2 Beta2))
kdelibs svn rev. 895869 / kdebase svn rev. 895869
Comment 2 Petri Damstén 2008-12-18 07:47:24 UTC
SVN commit 898392 by pdamsten:

activate layout to calculate fixed size ratio correctly on applet start.
BUG: 176268

 M  +2 -1      applet.cpp  


WebSVN link: http://websvn.kde.org/?view=rev&revision=898392