Summary: | [Nouveau/X11] Using "adjust all fonts" in kcm_fonts causes plasmashell visual corruption | ||
---|---|---|---|
Product: | [Plasma] plasmashell | Reporter: | Ahmad Samir <a.samirh78> |
Component: | general | Assignee: | David Edmundson <kde> |
Status: | REOPENED --- | ||
Severity: | normal | CC: | nate, plasma-bugs |
Priority: | NOR | Keywords: | X11-only |
Version: | master | ||
Target Milestone: | 1.0 | ||
Platform: | Other | ||
OS: | Linux | ||
Latest Commit: | Version Fixed In: | ||
Sentry Crash Report: | |||
Attachments: | Screenshot |
Definitely NVIDIA-related. (It affects the whole plasmashell, not just the panel). *** This bug has been marked as a duplicate of bug 449429 *** I think it's not a duplicate, since I am using X11 and the nouveau driver not the nvidia proprietary one. Oh ok. Adding the x11-only keyword |
Created attachment 146122 [details] Screenshot Using "adjust all fonts" in the fonts KCM to change the font, then clicking Apply, I get the panel corruption in the attached screenshot. The same corruption seems to extend to the desktop wallpaper too. Restarting KWin or Plasmashell seem to clear up the issue. Setup: - Plasma from a recent git snapshot from Tumbleweed repos - nvidia gtx770 with the nouveau kernel module and the modesetting driver - X11 - Mesa-dri-nouveau-21.3.4, libdrm_nouveau2-2.4.109 - kernel-5.16.2