Summary: | Double-clicking panel height numbers increases them instead of selecting them | ||
---|---|---|---|
Product: | [Frameworks and Libraries] libplasma | Reporter: | David <david.cortes.rivera> |
Component: | components | Assignee: | Marco Martin <notmart> |
Status: | RESOLVED FIXED | ||
Severity: | normal | CC: | nate, plasma-bugs |
Priority: | NOR | ||
Version: | 5.87.0 | ||
Target Milestone: | --- | ||
Platform: | Other | ||
OS: | Linux | ||
Latest Commit: | https://invent.kde.org/frameworks/plasma-framework/-/commit/d3af00fa0be5d1d124dabc45ee1f18e32cbc26f1 | Version Fixed In: | 5.88 |
Sentry Crash Report: |
Description
David
2021-10-24 20:05:44 UTC
It's true that double-click doesn't select the number, but I cannot reproduce the size change. I suspect you're actually dragging by accident with the double-click (or else your mouse or touchpad has some jitter). A possibly relevant merge request was started @ https://invent.kde.org/frameworks/plasma-framework/-/merge_requests/364 Fixed by Noah Davis with https://invent.kde.org/frameworks/plasma-framework/-/commit/d3af00fa0be5d1d124dabc45ee1f18e32cbc26f1 in frameworks 5.88! |