Bug 443093

Summary: In application/window settings dialog, bottom toolbar and "Add Property" button is missing until dialog is resized
Product: [Plasma] kwin Reporter: nyanpasu64 <nyanpasu64>
Component: rulesAssignee: KWin default assignee <kwin-bugs-null>
Status: RESOLVED DUPLICATE    
Severity: normal CC: isma.af
Priority: NOR    
Version: 5.22.90   
Target Milestone: ---   
Platform: Arch Linux   
OS: Linux   
Latest Commit: Version Fixed In:

Description nyanpasu64 2021-09-28 19:46:15 UTC
SUMMARY
If I right-click a window title bar and select More Actions -> Configure Special Window/Application Settings..., then I cannot add properties until I resize the dialog.

STEPS TO REPRODUCE
1. Right-click a window title bar.
2. Select More Actions -> Configure Special Window/Application Settings.

OBSERVED RESULT
The bottom toolbar containing the "Add Property..." button is missing until the window is resized.

EXPECTED RESULT
The bottom toolbar is present.

SOFTWARE/OS VERSIONS
Operating System: Arch Linux
KDE Plasma Version: 5.22.90
KDE Frameworks Version: 5.86.0
Qt Version: 5.15.2
Kernel Version: 5.14.7-zen1-1-zen (64-bit)
Graphics Platform: X11
Processors: 12 × AMD Ryzen 5 5600X 6-Core Processor
Memory: 15.6 GiB of RAM
Graphics Processor: NVIDIA GeForce GT 730/PCIe/SSE2

ADDITIONAL INFORMATION
Comment 1 Ismael Asensio 2021-09-28 19:48:01 UTC

*** This bug has been marked as a duplicate of bug 442660 ***