Summary: | Only the first sensor value is displayed in the popup | ||
---|---|---|---|
Product: | [Plasma] plasmashell | Reporter: | Antonio Rojas <arojas> |
Component: | System Monitor | Assignee: | Marco Martin <notmart> |
Status: | RESOLVED FIXED | ||
Severity: | normal | CC: | nate, noahadvs, plasma-bugs |
Priority: | NOR | ||
Version: | 5.19.0 | ||
Target Milestone: | 1.0 | ||
Platform: | Other | ||
OS: | Linux | ||
Latest Commit: | https://invent.kde.org/plasma/libksysguard/commit/3a133b7067c36e0ec36ea400908c7425ecacfdac | Version Fixed In: | 5.19.2 |
Sentry Crash Report: | |||
Attachments: | Screenshot |
The same happens if you add it to the desktop, but in that case you can resize it vertically to show all values. The panel popup can't be resized A possibly relevant merge request was started @ https://invent.kde.org/plasma/libksysguard/-/merge_requests/28 Git commit 3a133b7067c36e0ec36ea400908c7425ecacfdac by Marco Martin. Committed on 19/06/2020 at 08:24. Pushed by mart into branch 'Plasma/5.19'. expose better size hints expose size hints calculated better that make sure that when in popup the full legend is shown Related: bug 422888 M +2 -0 faces/facepackages/barchart/contents/ui/CompactRepresentation.qml M +9 -1 faces/facepackages/barchart/contents/ui/FullRepresentation.qml M +7 -0 faces/facepackages/linechart/contents/ui/FullRepresentation.qml M +9 -4 faces/facepackages/piechart/contents/ui/FullRepresentation.qml M +6 -0 faces/facepackages/textonly/contents/ui/FullRepresentation.qml https://invent.kde.org/plasma/libksysguard/commit/3a133b7067c36e0ec36ea400908c7425ecacfdac Still valid in 5.19.2 Git commit b7d7bfb0b88195e2b973b2ddc09eedf2810da88c by Marco Martin. Committed on 24/06/2020 at 09:40. Pushed by mart into branch 'Plasma/5.19'. better propagate size hints better propagate Layout.* hints from the loaded faces to the plasmoid object this helps in obtaining a more crorrectly sized popup Related: bug 422888 M +6 -6 applets/systemmonitor/systemmonitor/package/contents/ui/CompactRepresentation.qml M +8 -13 applets/systemmonitor/systemmonitor/package/contents/ui/FullRepresentation.qml M +8 -2 applets/systemmonitor/systemmonitor/package/contents/ui/main.qml https://invent.kde.org/plasma/plasma-workspace/commit/b7d7bfb0b88195e2b973b2ddc09eedf2810da88c This appears to be fixed now. Testing 5.26.1 |
Created attachment 129158 [details] Screenshot SUMMARY Adding a system monitor applet to the menu with two sensors, the popup only displays the (text) value of the first one. See screenshot EXPECTED RESULT SOFTWARE/OS VERSIONS Windows: macOS: Linux/KDE Plasma: (available in About System) KDE Plasma Version: KDE Frameworks Version: Qt Version: ADDITIONAL INFORMATION