Bug 308497

Summary: Setting the time format between 24 hour and 12 hour has no effect on the time in the top bar.
Product: [Plasma] Active Reporter: Jeremy Whiting <jpwhiting>
Component: Top BarAssignee: active
Status: RESOLVED UNMAINTAINED    
Severity: normal CC: notmart, thomas.pfeiffer
Priority: NOR    
Version: PA 3   
Target Milestone: unscheduled   
Platform: unspecified   
OS: Linux   
Latest Commit: Version Fixed In:

Description Jeremy Whiting 2012-10-16 15:14:56 UTC
After fixing the timezone in active-settings I expected the time in the top bar to follow the checkbox and use 12 hour format, but it didn't.  I tried toggling it on and off and it stayed the same.

Reproducible: Always



Expected Results:  
I expected the time format in the top bar to use the same format as specified in the time configuration screen.
Comment 1 Aaron J. Seigo 2012-10-17 18:53:28 UTC
24 hour clock is good enough for everyone ;) seriously though, if you restart the device does it pick up the setting correctly?
Comment 2 Jeremy Whiting 2012-10-17 19:06:58 UTC
Sure doesn't. Restarted and checked the checkbox is unchecked but the clock currently says 13:05.
Comment 3 Thomas Pfeiffer 2012-12-06 21:56:48 UTC
It switches immediately now. The non-24-hour clock is a bit small, but that's not what this bug is about, so I'll mark it as fixed.
Comment 4 Jeremy Whiting 2013-09-09 16:35:07 UTC
Just installed PA4 on exopc and it doesn't switch immediately here. In fact it never switches. Also if I switch to Screen and back to Time settings window, the options I changed are forgotten.

Also, the timezone doesn't seem to make any change and setting set time from pool.ntp.org doesn't update the clock here either.