Version: (using KDE 4.0.98) OS: Linux I had some plasmoid on the desktop, which I deleted from the harddisk before removing from the desktop. Hence plasma shows an empty plasmoid, which is ok. However, if I remove it and log out and back in, it is recreated again, which should not happen. Attached you will find the plasma rcs, the plasmoid I mean is just above the fuzzy-clock on the desktop.
Created attachment 26191 [details] appletsrc
Created attachment 26192 [details] plasmarc
this is the result of a bug on deletion of applets that's already been fixed. unfortunately, your plasma-appletsrc is now problematic (look for transform=0,0,0,0,0,0,1 type lines)
This is not fixed and unrelated to the transform line, since that line was only part of the fuzzy-clock applet and removing it while plasma is not running and deleting the mentioned plasmoid afterwards does not solve the issue. If you use my plasma* files you will see the blank applet above the fuzzy clock on the desktop.
Tested with Revision: 833687.
SVN commit 833967 by aseigo: associate broken applets with the id so they will be removedable (automatically at next start, even) BUG:166811 M +2 -4 containment.cpp WebSVN link: http://websvn.kde.org/?view=rev&revision=833967