Bug 154329

Summary: Plasma applet handle icons should appear closest to the centre of the screen
Product: [Plasma] plasma4 Reporter: Mike <mike>
Component: containment-desktopAssignee: Plasma Bugs List <plasma-bugs>
Status: RESOLVED FIXED    
Severity: wishlist CC: aseigo, finex, rusty
Priority: NOR    
Version: unspecified   
Target Milestone: ---   
Platform: Compiled Sources   
OS: Linux   
Latest Commit: Version Fixed In:

Description Mike 2007-12-19 16:29:00 UTC
Version:            (using KDE Devel)
Installed from:    Compiled sources
OS:                Linux

If you add a plasmoid to the desktop in the top left corner and then try to resize it bigger, you cannot because the icons on the applethandle are on the edge of the screen.  A similar problem happens if you put it on the top right of the screen.  You cannot make it bigger without moving it first, it rotates if you try.
Comment 1 Gael Beaudoin 2008-03-10 21:45:48 UTC
In trunk r783025 it's not true anymore : when on the left edge, controls apears on the right and vice versa.

So this is fixed/done I think.
Comment 2 Chani 2008-03-12 09:37:03 UTC
not quite. they'll switch between left and right, but still be at the top even if only the bottom half of the applet is onscreen.
Comment 3 FiNeX 2008-11-11 15:14:55 UTC
*** Bug 174865 has been marked as a duplicate of this bug. ***
Comment 4 FiNeX 2008-11-11 15:15:50 UTC
This is an example: http://bugs.kde.org/attachment.cgi?id=28495
Comment 5 Aaron J. Seigo 2008-11-19 05:57:59 UTC
they appear closest to the mouse entry point, assuming it fits on screen.