| Summary: | KDE Partition Manager not showing SMART info correctly | ||
|---|---|---|---|
| Product: | [Applications] partitionmanager | Reporter: | semlraug |
| Component: | general | Assignee: | Andrius Štikonas <andrius> |
| Status: | RESOLVED DUPLICATE | ||
| Severity: | normal | CC: | semlraug |
| Priority: | NOR | ||
| Version First Reported In: | 25.12.0 | ||
| Target Milestone: | --- | ||
| Platform: | Other | ||
| OS: | Linux | ||
| Latest Commit: | Version Fixed/Implemented In: | ||
| Sentry Crash Report: | |||
| Attachments: | screenshot of part of the partition manager screen showing the wrong info | ||
Sorry, forgot to add the system info: Operating System: EndeavourOS KDE Plasma Version: 6.5.4 KDE Frameworks Version: 6.21.0 Qt Version: 6.10.1 Kernel Version: 6.12.63-1-lts (64-bit) Graphics Platform: Wayland That's because it's NVMe, NVMe SMART parsing is not implemented (it's in a different format than SATA drives) *** This bug has been marked as a duplicate of bug 422877 *** |
Created attachment 188268 [details] screenshot of part of the partition manager screen showing the wrong info SUMMARY STEPS TO REPRODUCE 1. open partition manager; 2. in the "devices" section right click the name of the ssd 3. Select SMART Status OBSERVED RESULT Kde shows the temp of the drive being -273, although it reports the disk as being healthy. No further SMART properties are being shown EXPECTED RESULT SMART info as smartctl reports it: smartctl 7.5 2025-04-30 r5714 [x86_64-linux-6.12.63-1-lts] (local build) Copyright (C) 2002-25, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Number: WD PC SN5000S SDEPNSJ-512G-1001 Serial Number: 252440401497 Firmware Version: 34250001 PCI Vendor/Subsystem ID: 0x15b7 IEEE OUI Identifier: 0x001b44 Total NVM Capacity: 512.110.190.592 [512 GB] Unallocated NVM Capacity: 0 Controller ID: 1 NVMe Version: 2.0 Number of Namespaces: 1 Namespace 1 Size/Capacity: 512.110.190.592 [512 GB] Namespace 1 Formatted LBA Size: 512 Namespace 1 IEEE EUI-64: 001b44 4a458199c9 Local Time is: Tue Jan 6 15:08:56 2026 CET Firmware Updates (0x14): 2 Slots, no Reset required Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test Optional NVM Commands (0x00df): Comp Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat Timestmp Verify Log Page Attributes (0x7e): Cmd_Eff_Lg Ext_Get_Lg Telmtry_Lg Pers_Ev_Lg Log0_FISE_MI Telmtry_Ar_4 Maximum Data Transfer Size: 128 Pages Warning Comp. Temp. Threshold: 90 Celsius Critical Comp. Temp. Threshold: 92 Celsius Namespace 1 Features (0x92): NA_Fields NP_Fields *Other* Supported Power States St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat 0 + 5.00W 5.00W - 0 0 0 0 0 0 1 + 3.00W 3.00W - 0 0 0 0 0 0 2 + 2.50W 2.50W - 0 0 0 0 0 0 3 - 0.0200W - - 3 3 3 3 2000 3000 4 - 0.0050W - - 4 4 4 4 4000 12000 5 - 0.0030W - - 5 5 5 5 176000 25000 Supported LBA Sizes (NSID 0x1) Id Fmt Data Metadt Rel_Perf 0 + 512 0 2 1 - 4096 0 1 === START OF SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED SMART/Health Information (NVMe Log 0x02, NSID 0xffffffff) Critical Warning: 0x00 Temperature: 21 Celsius Available Spare: 100% Available Spare Threshold: 10% Percentage Used: 0% Data Units Read: 3.247.935 [1,66 TB] Data Units Written: 743.893 [380 GB] Host Read Commands: 8.786.706 Host Write Commands: 8.597.295 Controller Busy Time: 39 Power Cycles: 63 Power On Hours: 18 Unsafe Shutdowns: 2 Media and Data Integrity Errors: 0 Error Information Log Entries: 0 Warning Comp. Temperature Time: 0 Critical Comp. Temperature Time: 0 Temperature Sensor 1: 20 Celsius Temperature Sensor 2: 21 Celsius Error Information (NVMe Log 0x01, 16 of 256 entries) No Errors Logged Self-test Log (NVMe Log 0x06, NSID 0xffffffff) Self-test status: No self-test in progress SOFTWARE/OS VERSIONS Windows: macOS: (available in the Info Center app, or by running `kinfo` in a terminal window) Linux/KDE Plasma: KDE Plasma Version: KDE Frameworks Version: Qt Version: ADDITIONAL INFORMATION