Summary: | Discover cannot perform a firmware update | ||
---|---|---|---|
Product: | [Applications] Discover | Reporter: | bluelupo <info> |
Component: | discover | Assignee: | Plasma Bugs List <plasma-bugs-null> |
Status: | RESOLVED WORKSFORME | ||
Severity: | normal | CC: | aleixpol, kde |
Priority: | NOR | ||
Version First Reported In: | 6.4.1 | ||
Target Milestone: | --- | ||
Platform: | Neon | ||
OS: | Linux | ||
Latest Commit: | Version Fixed In: | ||
Sentry Crash Report: | |||
Attachments: | screenshot from discover |
Description
bluelupo
2025-06-30 11:36:17 UTC
Additional info from fwupdmgr. Perhaps there is a connection to the error report from me. See section "System Firmware" │ │ Vendor: Lenovo (DMI:LENOVO) │ │ Update State: Failed │ │ Update Error: failed to update to 0: error-invalid-format # fwupdmgr get-devices LENOVO 30H0005TGE │ ├─Core™ i5-14600: │ Device ID: 4bde70ba4e39b28f9eab1628f9dd6e6244c03027 │ Current version: 0x0000012f │ Vendor: Intel │ GUID: 3d4645d8-13fe-541a-ac5c-7d9d944e4500 ← CPUID\PRO_0&FAM_06&MOD_B7 │ 988c4cf1-ace4-5eb5-b26c-905ff236f412 ← CPUID\PRO_0&FAM_06&MOD_B7&STP_1 │ Device Flags: • Internal device │ ├─Embedded Controller: │ Device ID: a0bf4dea6a1a458a89bbc7c99cbad9a90c5daf65 │ Summary: UEFI System Resource Table device (Updated via capsule-on-disk) │ Current version: 0.1.19 │ Minimum Version: 0.1.19 │ Vendor: Lenovo (DMI:LENOVO) │ Update State: Success │ GUID: 44b9f325-7ea2-4c2a-a8b1-a67e0c554932 │ Device Flags: • Internal device │ • Updatable │ • System requires external power source │ • Supported on remote server │ • Needs a reboot after installation │ • Device is usable for the duration of the update │ Device Requests: • Message │ ├─Lexar SSD NM790 4TB: │ Device ID: 71b677ca0f1bc2c5b804fa1d59e52064ce589293 │ Summary: NVM Express solid state drive │ Current version: V4.0.4 │ Vendor: Shenzhen Longsys Electronics Co., Ltd. (NVME:0x1D97) │ Serial Number: QCF361R001304P220J │ GUID: ecfec37e-e02d-5dc8-86b7-b048da224754 ← NVME\VEN_1D97&DEV_1602 │ d1827d33-5ac2-57f0-ba49-d8e444f2f8e6 ← NVME\VEN_1D97&DEV_1602&SUBSYS_1D971602 │ 7a09c774-3a90-51cc-bc99-e8784cb5aee0 ← Lexar SSD NM790 4TB │ Device Flags: • Internal device │ • Updatable │ • System requires external power source │ • Needs a reboot after installation │ • Device is usable for the duration of the update │ ├─Raptor Lake-S GT1 [UHD Graphics 770]: │ Device ID: 5792b48846ce271fab11c4a545f7a3df0d36e00a │ Current version: 04 │ Vendor: Intel Corporation (PCI:0x8086) │ GUID: d2e34a7c-ed41-5be7-bc67-304c11008b77 ← PCI\VEN_8086&DEV_A780 │ 132d0a28-3949-57a0-80b1-dce85576b4fb ← PCI\VEN_8086&DEV_A780&SUBSYS_17AA3333 │ Device Flags: • Internal device │ • Cryptographic hash verification is available │ ├─System Firmware: │ │ Device ID: 32216088075afb6a4d591c6c612ab8d2b064aec8 │ │ Summary: UEFI System Resource Table device (Updated via capsule-on-disk) │ │ Current version: 0.1.82 │ │ Minimum Version: 0.1.82 │ │ Vendor: Lenovo (DMI:LENOVO) │ │ Update State: Failed │ │ Update Error: failed to update to 0: error-invalid-format │ │ GUID: 8a15883b-8f20-4aaf-a7d8-ceb35316fb3d │ │ Device Flags: • Internal device │ │ • Updatable │ │ • System requires external power source │ │ • Supported on remote server │ │ • Needs a reboot after installation │ │ • Cryptographic hash verification is available │ │ • Device is usable for the duration of the update │ │ Device Requests: • Message │ │ │ ├─AMT [unprovisioned]: │ │ Device ID: 8d5470e73fd9a31eaa460b2b6aea95483fe3f14c │ │ Summary: Hardware and firmware technology for remote out-of-band management │ │ Current version: 16.1.30.2307 │ │ Bootloader Version:16.1.30.2307 │ │ Vendor: Intel Corporation (MEI:0x8086) │ │ GUID: 12f80028-b4b7-4b2d-aca8-46e0ff65814c │ │ 3244e2f4-fbe1-5e67-8c66-1c9936061c21 ← MEI\VEN_8086&DEV_7AE8 │ │ 679865e1-8c7d-5169-a8c8-415bdbfcfc8c ← MEI\VEN_8086&DEV_7AE8&SUBSYS_17AA3333 │ │ Device Flags: • Internal device │ │ │ ├─BootGuard Configuration: │ │ Device ID: b0d4430dfa6bde9f0c22680df36dbc8c15c80753 │ │ Current version: 11 │ │ Vendor: Intel Corporation (MEI:0x8086) │ │ GUID: dd17041c-09ea-4b17-a271-5b989867ec65 │ │ 3244e2f4-fbe1-5e67-8c66-1c9936061c21 ← MEI\VEN_8086&DEV_7AE8 │ │ 679865e1-8c7d-5169-a8c8-415bdbfcfc8c ← MEI\VEN_8086&DEV_7AE8&SUBSYS_17AA3333 │ │ Device Flags: • Internal device │ │ │ └─UEFI dbx: │ Device ID: 362301da643102b9f38477387e2193e57abaa590 │ Summary: UEFI revocation database │ Current version: 20230501 │ Minimum Version: 20230501 │ Vendor: UEFI:Microsoft │ Install Duration: 1 second │ GUID: d07ff664-b0e1-5f4e-a723-d7fbcbfcb94f ← UEFI\CRT_3CD3F0309EDAE228767A976DD40D9F4AFFC4FBD5218F2E8CC3C9DD97E8AC6F9D&ARCH_X64 │ 25c2b9af-7c95-564e-9b07-eccceacb46e8 ← UEFI\CRT_B4731FEF902AA3DA869F0803C84D732D790B0C23D095EDB2CCCCCB304FB00C53&ARCH_X64 │ f8ba2887-9411-5c36-9cee-88995bb39731 ← UEFI\CRT_A1117F516A32CEFCBA3F2D1ACE10A87972FD6BBE8FE0D0B996E09E65D802A503&ARCH_X64 │ Device Flags: • Internal device │ • Updatable │ • Needs a reboot after installation │ • Device is usable for the duration of the update │ • Only version upgrades are allowed │ • Signed Payload │ ├─TPM: │ Device ID: 0fcbfb82d017c4f44187fcd191953c69ac94ec88 │ Summary: UEFI System Resource Table device (Updated via capsule-on-disk) │ Current version: 23.69.0 │ Minimum Version: 23.69.0 │ Vendor: Lenovo (DMI:LENOVO) │ Update State: Success │ GUID: 2327d974-d5a6-4f5e-909a-94229bd95964 │ Device Flags: • Internal device │ • Updatable │ • System requires external power source │ • Supported on remote server │ • Needs a reboot after installation │ • Device is usable for the duration of the update │ Device Requests: • Message │ ├─TPM: │ Device ID: c6a80ac3a22083423992a3cb15018989f37834d6 │ Current version: 15.23.69.0 │ Vendor: Infineon (TPM:IFX) │ GUID: 5eebb112-75ad-5536-b173-a11eb3399402 ← TPM\VEN_IFX&DEV_0000 │ 0df86b23-72b8-5128-9fc2-3377446e8ecf ← TPM\VEN_IFX&MOD_SLB9672 │ 6d81ab63-db2e-50ac-934f-6be9accf5e02 ← TPM\VEN_IFX&DEV_0000&VER_2.0 │ 13249df8-c159-574a-b877-b045aa40bc54 ← TPM\VEN_IFX&MOD_SLB9672&VER_2.0 │ Device Flags: • Internal device │ • System requires external power source │ • Needs a reboot after installation │ • Device can recover flash failures │ • Full disk encryption secrets may be invalidated when updating │ • Signed Payload │ ├─UEFI Device Firmware: │ Device ID: a7587d2963da911f83a7551320e96382dc30c6f5 │ Summary: UEFI System Resource Table device (Updated via capsule-on-disk) │ Current version: 2703100163 │ Minimum Version: 2703100163 │ Vendor: DMI:LENOVO │ Update State: Success │ GUID: 7fd2a343-8917-48a5-8aa6-b47edd8431cd │ Device Flags: • Internal device │ • Updatable │ • System requires external power source │ • Needs a reboot after installation │ • Device is usable for the duration of the update │ Device Requests: • Message │ └─WDC WD120EDBZ-11B1HA0: Device ID: f5b57bf2e604674c1c969c56db7df6fc1864a281 Summary: ATA drive Current version: 85.00A85 Vendor: Western Digital (ATA:0x101C, OUI:000cca) Serial Number: D7H7ZMSN GUID: 3bb9bc60-a729-59c7-88a6-ed08aeeccbd7 ← IDE\WDC_WD120EDBZ-11B1HA0___________________85.00A85 a46dd3f9-0124-5ef0-986b-1207d5c09e95 ← IDE\0WDC_WD120EDBZ-11B1HA0___________________ 67a7aed0-f973-50e9-8ef2-52953cdab9c6 ← WDC WD120EDBZ-11B1HA0 Device Flags: • Updatable • System requires external power source • Needs a reboot after installation Can you install the firmware update manually via fwupd? It'll show if it's an issue in discover or lower in the stack. If fwupd has any errors if you could let us know that would be great. (In reply to David Edmundson from comment #2) > Can you install the firmware update manually via fwupd? It'll show if it's > an issue in discover or lower in the stack. > If fwupd has any errors if you could let us know that would be great. Hi David, Yes, I can do that if I know how to update the two packages. Can you give me the commands for the command line? Unfortunately I have never worked with fwupd before. Greetings Michael (bluelupo) I have now found the information on the net how to update the firmware on the command line via “fwupdmgr”. I executed the following commands as root: # fwupdmgr refresh --force # fwupdmgr get-updates # fwupdmgr update Everything went through without errors, but unfortunately the packages... “Lenovo System Firmware 0.1.82 --> 0.1.86” “Lenovo TPM 23.69.0 --> 24.74.2560” ...are still displayed in Discover. As in my first post attached screenshot. Here again the output of “fwupdmgr get-updates” after the update. # fwupdmgr get-updates Devices with no available firmware updates: • Lexar SSD NM790 4TB • UEFI Device Firmware • UEFI dbx Devices with the latest available firmware version: • Embedded Controller LENOVO 30H0005TGE │ ├─System Firmware: │ │ Device ID: 32216088075afb6a4d591c6c612ab8d2b064aec8 │ │ Summary: UEFI System Resource Table device (Updated via capsule-on-disk) │ │ Current version: 0.1.82 │ │ Minimum Version: 0.1.82 │ │ Vendor: Lenovo (DMI:LENOVO) │ │ Update State: Failed │ │ Update Error: failed to update to 0: error-invalid-format │ │ GUID: 8a15883b-8f20-4aaf-a7d8-ceb35316fb3d │ │ Device Flags: • Internal device │ │ • Updatable │ │ • System requires external power source │ │ • Supported on remote server │ │ • Needs a reboot after installation │ │ • Cryptographic hash verification is available │ │ • Device is usable for the duration of the update │ │ Device Requests: • Message │ │ │ ├─ThinkCentre M90q-4 M80q-4 P3Tiny System Update: │ │ New version: 0.1.86 │ │ Remote ID: lvfs │ │ Release ID: 115373 │ │ Summary: System Firmware for ThinkCentre M90q-4 M80q-4 P3Tiny │ │ License: Proprietary │ │ Size: 16,9 MB │ │ Created: 2025-06-09 │ │ Urgency: Low │ │ Tested by Lenovo: │ │ Tested: 2025-06-09 │ │ Distribution: rhel 9.4 │ │ Old version: 0.1.85 │ │ Version[fwupd]: 1.9.13 │ │ Vendor: Lenovo │ │ Release Flags: • Trusted metadata │ │ • Is upgrade │ │ • Tested by trusted vendor │ │ Description: │ │ This stable release fixes the following issues: │ │ │ │ • Add Microsoft Corp DB Ca and option rom db ca 2023. │ │ • Enhancement to address security vulnerability. │ │ • Fix a BIOS Setup issue. │ │ • Fix a Linux Firmware Update issue. │ │ • Update Cpu Micorcode. │ │ • Fix a WMI issue. │ │ Issues: CVE-2024-38796 │ │ CVE-2025-20623 │ │ CVE-2024-45332 │ │ CVE-2024-43420 │ │ CVE-2025-20054 │ │ CVE-2025-20109 │ │ CVE-2025-20044 │ │ CVE-2025-22830 │ │ CVE-2025-22834 │ │ Checksum: 66cc17127837a04229d76f65ddf4ee613d850bc45ba0a920e178d55ed23d1c5a │ │ │ ├─ThinkCentre M90q-4 M80q-4 P3Tiny System Update: │ │ New version: 0.1.85 │ │ Remote ID: lvfs │ │ Release ID: 111551 │ │ Summary: System Firmware for ThinkCentre M90q-4 M80q-4 P3Tiny │ │ License: Proprietary │ │ Size: 16,9 MB │ │ Created: 2025-04-14 │ │ Urgency: Low │ │ Tested by Lenovo: │ │ Tested: 2025-04-16 │ │ Distribution: ubuntu 24.04 │ │ Old version: 0.1.84 │ │ Version[fwupd]: 1.9.28 │ │ Vendor: Lenovo │ │ Release Flags: • Trusted metadata │ │ • Is upgrade │ │ • Tested by trusted vendor │ │ Description: │ │ This stable release fixes the following issues: │ │ │ │ • Add WiFi 6E support for some countries. │ │ • Fix a WMI item spelling issue. │ │ • Add “Primary Display” support for P3 Tiny. │ │ • Add WiFi 6E support for some countries. │ │ • Enhancement to address security vulnerability. │ │ Issues: CVE-2024-36262 │ │ CVE-2024-30211 │ │ CVE-2024-26021 │ │ CVE-2024-24582 │ │ CVE-2024-48366 │ │ Checksum: 26160ea329cb9cd3c50a0629f7a527c89eee2bbe74ea64818807c7ace184bacc │ │ │ └─ThinkCentre M90q-4 M80q-4 P3Tiny System Update: │ New version: 0.1.84 │ Remote ID: lvfs │ Release ID: 105578 │ Summary: System Firmware for ThinkCentre M90q-4 M80q-4 P3Tiny │ License: Proprietary │ Size: 16,9 MB │ Created: 2025-01-15 │ Urgency: Low │ Tested by Lenovo: │ Tested: 2025-01-15 │ Distribution: ubuntu 24.04 │ Old version: 0.1.83 │ Version[fwupd]: 1.9.16 │ Vendor: Lenovo │ Release Flags: • Trusted metadata │ • Is upgrade │ • Tested by trusted vendor │ Description: │ This stable release fixes the following issues: │ │ • Fixed some Reset system to Factory Default and one key Disposal related Issue. │ Checksum: a1ae9ee21204fc3ea3e22e17a23da42db4ced4dab8297531e9bc4c166470c01d │ └─TPM: │ Device ID: 0fcbfb82d017c4f44187fcd191953c69ac94ec88 │ Summary: UEFI System Resource Table device (Updated via capsule-on-disk) │ Current version: 23.69.0 │ Minimum Version: 23.69.0 root@sunlight:~# fwupdmgr get-updates Devices with no available firmware updates: • Lexar SSD NM790 4TB • UEFI Device Firmware • UEFI dbx Devices with the latest available firmware version: • Embedded Controller LENOVO 30H0005TGE │ ├─System Firmware: │ │ Device ID: 32216088075afb6a4d591c6c612ab8d2b064aec8 │ │ Summary: UEFI System Resource Table device (Updated via capsule-on-disk) │ │ Current version: 0.1.82 │ │ Minimum Version: 0.1.82 │ │ Vendor: Lenovo (DMI:LENOVO) │ │ Update State: Failed │ │ Update Error: failed to update to 0: error-invalid-format │ │ GUID: 8a15883b-8f20-4aaf-a7d8-ceb35316fb3d │ │ Device Flags: • Internal device │ │ • Updatable │ │ • System requires external power source │ │ • Supported on remote server │ │ • Needs a reboot after installation │ │ • Cryptographic hash verification is available │ │ • Device is usable for the duration of the update │ │ Device Requests: • Message │ │ │ ├─ThinkCentre M90q-4 M80q-4 P3Tiny System Update: │ │ New version: 0.1.86 │ │ Remote ID: lvfs │ │ Release ID: 115373 │ │ Summary: System Firmware for ThinkCentre M90q-4 M80q-4 P3Tiny │ │ License: Proprietary │ │ Size: 16,9 MB │ │ Created: 2025-06-09 │ │ Urgency: Low │ │ Tested by Lenovo: │ │ Tested: 2025-06-09 │ │ Distribution: rhel 9.4 │ │ Old version: 0.1.85 │ │ Version[fwupd]: 1.9.13 │ │ Vendor: Lenovo │ │ Release Flags: • Trusted metadata │ │ • Is upgrade │ │ • Tested by trusted vendor │ │ Description: │ │ This stable release fixes the following issues: │ │ │ │ • Add Microsoft Corp DB Ca and option rom db ca 2023. │ │ • Enhancement to address security vulnerability. │ │ • Fix a BIOS Setup issue. │ │ • Fix a Linux Firmware Update issue. │ │ • Update Cpu Micorcode. │ │ • Fix a WMI issue. │ │ Issues: CVE-2024-38796 │ │ CVE-2025-20623 │ │ CVE-2024-45332 │ │ CVE-2024-43420 │ │ CVE-2025-20054 │ │ CVE-2025-20109 │ │ CVE-2025-20044 │ │ CVE-2025-22830 │ │ CVE-2025-22834 │ │ Checksum: 66cc17127837a04229d76f65ddf4ee613d850bc45ba0a920e178d55ed23d1c5a │ │ │ ├─ThinkCentre M90q-4 M80q-4 P3Tiny System Update: │ │ New version: 0.1.85 │ │ Remote ID: lvfs │ │ Release ID: 111551 │ │ Summary: System Firmware for ThinkCentre M90q-4 M80q-4 P3Tiny │ │ License: Proprietary │ │ Size: 16,9 MB │ │ Created: 2025-04-14 │ │ Urgency: Low │ │ Tested by Lenovo: │ │ Tested: 2025-04-16 │ │ Distribution: ubuntu 24.04 │ │ Old version: 0.1.84 │ │ Version[fwupd]: 1.9.28 │ │ Vendor: Lenovo │ │ Release Flags: • Trusted metadata │ │ • Is upgrade │ │ • Tested by trusted vendor │ │ Description: │ │ This stable release fixes the following issues: │ │ │ │ • Add WiFi 6E support for some countries. │ │ • Fix a WMI item spelling issue. │ │ • Add “Primary Display” support for P3 Tiny. │ │ • Add WiFi 6E support for some countries. │ │ • Enhancement to address security vulnerability. │ │ Issues: CVE-2024-36262 │ │ CVE-2024-30211 │ │ CVE-2024-26021 │ │ CVE-2024-24582 │ │ CVE-2024-48366 │ │ Checksum: 26160ea329cb9cd3c50a0629f7a527c89eee2bbe74ea64818807c7ace184bacc │ │ │ └─ThinkCentre M90q-4 M80q-4 P3Tiny System Update: │ New version: 0.1.84 │ Remote ID: lvfs │ Release ID: 105578 │ Summary: System Firmware for ThinkCentre M90q-4 M80q-4 P3Tiny │ License: Proprietary │ Size: 16,9 MB │ Created: 2025-01-15 │ Urgency: Low │ Tested by Lenovo: │ Tested: 2025-01-15 │ Distribution: ubuntu 24.04 │ Old version: 0.1.83 │ Version[fwupd]: 1.9.16 │ Vendor: Lenovo │ Release Flags: • Trusted metadata │ • Is upgrade │ • Tested by trusted vendor │ Description: │ This stable release fixes the following issues: │ │ • Fixed some Reset system to Factory Default and one key Disposal related Issue. │ Checksum: a1ae9ee21204fc3ea3e22e17a23da42db4ced4dab8297531e9bc4c166470c01d │ └─TPM: │ Device ID: 0fcbfb82d017c4f44187fcd191953c69ac94ec88 │ Summary: UEFI System Resource Table device (Updated via capsule-on-disk) │ Current version: 23.69.0 │ Minimum Version: 23.69.0 │ Vendor: Lenovo (DMI:LENOVO) │ Update State: Success │ GUID: 2327d974-d5a6-4f5e-909a-94229bd95964 │ Device Flags: • Internal device │ • Updatable │ • System requires external power source │ • Supported on remote server │ • Needs a reboot after installation │ • Device is usable for the duration of the update │ Device Requests: • Message │ └─ThinkCentre M90q-4 M80q-4 P3Tiny TPM Update: New version: 24.74.2560 Remote ID: lvfs Release ID: 111949 Summary: TPM Firmware for ThinkCentre M90q-4 M80q-4 P3Tiny License: Proprietary Size: 1,4 MB Created: 2025-04-25 Urgency: Low Tested by Lenovo: Tested: 2025-05-23 Distribution: ubuntu 24.04 Old version: 21.64.11776 Version[fwupd]: 1.9.16 Vendor: Lenovo Release Flags: • Trusted metadata • Is upgrade • Tested by trusted vendor Description: This stable release fixes the following issues: • Tpm TPM Firmware 15.24.18954.0 Formal Release for ThinkCentre M90q-4 M80q-4 P3Tiny Checksum: 6ef73c6afa739ee5f53e747eed30e4ae6eba4aca7216cc15f2894b5476b3cfe9 The packages have probably not been updated. What is going wrong here? Greetings Michael (bluelupo) 🐛🧹 ⚠️ This bug has been in NEEDSINFO status with no change for at least 15 days. Please provide the requested information, then set the bug status to REPORTED. If there is no change for at least 30 days, it will be automatically closed as RESOLVED WORKSFORME. For more information about our bug triaging procedures, please read https://community.kde.org/Guidelines_and_HOWTOs/Bug_triaging. Thank you for helping us make KDE software even better for everyone! 🐛🧹 This bug has been in NEEDSINFO status with no change for at least 30 days. Closing as RESOLVED WORKSFORME. |