Bug 494468

Summary: Calibration screen appears on wrong monitor
Product: [Applications] systemsettings Reporter: donovan.delaughter
Component: kcm_tabletAssignee: Plasma Bugs List <plasma-bugs>
Status: RESOLVED FIXED    
Severity: normal CC: aleixpol, josh, nate
Priority: NOR Keywords: multiscreen, usability
Version: 6.2.0   
Target Milestone: ---   
Platform: Arch Linux   
OS: Linux   
Latest Commit: Version Fixed In: 6.2.1
Sentry Crash Report:
Attachments: Monitor layout

Description donovan.delaughter 2024-10-10 16:38:46 UTC
SUMMARY
When calibrating a pen tablet, the calibration window appears on the wrong monitor. I have to manually move it to my pen tablet screen.

STEPS TO REPRODUCE
1. Make the pen tablet not the monitor at 0,0
2. Start the calibration
3. The calibration window appears on the wrong screen.

OBSERVED RESULT
The calibration window appears on the wrong screen.


EXPECTED RESULT
The calibration window appears on the pen tablet display.

SOFTWARE/OS VERSIONS
Linux: Arch Linux 
KDE Plasma Version: 6.2.0
KDE Frameworks Version: 6.6.0
Qt Version: 6.7.3
Graphics Platform: Wayland
Comment 1 Nate Graham 2024-10-10 19:55:23 UTC
How many screens to you have, and which one do you expect it to appear on? It would be great if you could trigger the issue and then take a photo of your setup, so we can see the hardware configuration and what incorrect screen the calibration overlay appears on.

Thanks a lot!
Comment 2 donovan.delaughter 2024-10-11 13:56:39 UTC
Created attachment 174689 [details]
Monitor layout

GT-191 is my drawing tablet
Comment 3 donovan.delaughter 2024-10-11 14:05:48 UTC
Here is a video of me demonstrating the behavior. Of note the bottom right monitor (GT-191) is my drawing tablet. And on the Drawing Tablet menu, it is set to map to that screen. In the video, I manually move the calibration window.
Comment 4 donovan.delaughter 2024-10-11 14:05:55 UTC
https://youtu.be/0MzHKFvTEec
Comment 5 Joshua Goins 2024-10-14 23:16:56 UTC
Fixed this, but only saw the bug later: https://invent.kde.org/plasma/plasma-desktop/-/merge_requests/2575