| Summary: | Horizontal Bars widget appearance option in KDE6 produces blank widget | ||
|---|---|---|---|
| Product: | [Plasma] plasmashell | Reporter: | MarkW <instruform> |
| Component: | System Monitor widgets | Assignee: | Plasma Bugs List <plasma-bugs-null> |
| Status: | RESOLVED DUPLICATE | ||
| Severity: | normal | CC: | ahiemstra, notmart |
| Priority: | NOR | ||
| Version First Reported In: | 6.0.2 | ||
| Target Milestone: | 1.0 | ||
| Platform: | Other | ||
| OS: | Linux | ||
| Latest Commit: | Version Fixed/Implemented In: | ||
| Sentry Crash Report: | |||
| Attachments: | Journal log | ||
*** This bug has been marked as a duplicate of bug 483947 *** |
Created attachment 167793 [details] Journal log SUMMARY When selecting a widget that uses multiple sources of data in KDE6, such as `Individual Core Usage`, selecting `Horizontal Bars` results in the widget not being displayed on the taskbar. STEPS TO REPRODUCE 1. Right Click on Taskbar and select `Add Widgets`. 2. Select `Individual Core Usage` widget, which then displays the widget. 3. Drag the widget to the taskbar. 4. Right click on the created widget and select `Configure Individual Core Usage...` 5. In the `Appearance` tab, select the dropdown menu to the right of `Display Style:` and select `Horizontal Bars`. 6. Click Apply. OBSERVED RESULT The widget no longer shows a vertical-bar graph and shows an empty space instead. EXPECTED RESULT The widget should change from a vertical bar chart to a horizontal bar chart. SOFTWARE/OS VERSIONS Linux/KDE Plasma: KDE Plasma Version: 6.0.2 KDE Frameworks Version: 6.0.0 Qt Version: 6.6.2 ADDITIONAL INFORMATION 1. The attached journal does report some anomalies when the attempt to change to `Horiztontal Bars` is attempted. 2. Sometimes, the widget will display text instead of bars after selecting and applying `Horizontal Bars`. 2. When I try to revert the change on the widget by changing it back to `Bar Chart`, it stays broken.