Description Bacteria 2023-11-12 05:52:47 UTC
SUMMARY
Panel stops defloating after turning off "Auto hide" option. 

STEPS TO REPRODUCE
1. Enable floating panel
2. Enter edit mode and enable "Auto-Hide" for panel. You don't need to do it if already done. 
2. Disable "Auto hide"

OBSERVED RESULT
Panel stop defloating when a window touches it.

EXPECTED RESULT
Panel should defloat when a window touches it.

SOFTWARE/OS 
Linux/KDE Plasma: Arch Linux
KDE Plasma Version: git master
KDE Frameworks Version: git master
Qt Version: 6.6.0

ADDITIONAL INFORMATION
You need to restart plasmashell to get the functionality back.
Comment 1 Nate Graham 2023-11-14 22:18:53 UTC
Can reproduce. I suspect it's related to Bug 476757.
Comment 2 Niccolò Venerandi 2023-11-20 11:06:26 UTC
Git commit 2ecfd25bcc1b817921eb15d77dfe0d9781b96028 by Niccolò Venerandi.
Committed on 20/11/2023 at 12:06.
Pushed by niccolove into branch 'master'.

Emit signal when showingDesktop changes in Wayland
Related: bug 476757, bug 475539

M  +1    -0    src/platforms/wayland/windowsystem.cpp

https://invent.kde.org/frameworks/kwindowsystem/-/commit/2ecfd25bcc1b817921eb15d77dfe0d9781b96028