Bug 468665

Summary: Plasma 5.27.4: Desktop icon positions get reset after changing monitor signal or reconnecting cable
Product: [Plasma] plasmashell Reporter: C. Kimna <kimna>
Component: Desktop icons & Folder View widgetAssignee: Plasma Bugs List <plasma-bugs>
Status: RESOLVED DUPLICATE    
Severity: normal CC: hein, nate
Priority: NOR    
Version: 5.27.4   
Target Milestone: 1.0   
Platform: Neon   
OS: Linux   
Latest Commit: Version Fixed In:
Sentry Crash Report:

Description C. Kimna 2023-04-18 20:42:37 UTC
SUMMARY
Situation: Monitor with multi-signal input. After switching back to KDE the icon positions on
desktop have been reset. Same issue after disconnecting monitor cable.


STEPS TO REPRODUCE
1. switch to another signal on monitor or plug off the monitor cable.
2. switch back to signal to KDE or replug the cable


OBSERVED RESULT
Desktop icons get reset to default positions (populating the top of the screen)

EXPECTED RESULT
Desktop icons hold their positions.

SOFTWARE/OS VERSIONS
Linux/KDE Plasma: Neon 5.27
KDE Plasma Version: 5.27.4
KDE Frameworks Version: 5.105.0
Qt Version: 5.15.8
Kernel Version: 5.15.0-69-generic 64-Bit


ADDITIONAL INFORMATION
Wayland: issue is persisting after removing kscreen.
Xorg: issue is gone after removing kscreen.

"kscreen-console monitor" displays while switching to other signal:
Priorities changed: QMap()
qt.qpa.wayland: Creating a fake screen in order for Qt not to crash
Comment 1 Nate Graham 2023-04-19 16:54:09 UTC

*** This bug has been marked as a duplicate of bug 467092 ***