Bug 428375

Summary: System monitor sensor widget details window is blank after upgrade to plasma 5.20
Product: [Plasma] plasmashell Reporter: BugCoder <bugcoder>
Component: System Monitor widgetsAssignee: Marco Martin <notmart>
Status: RESOLVED FIXED    
Severity: normal CC: ahiemstra, mmerlone, nate, plasma-bugs-null
Priority: NOR    
Version First Reported In: 5.20.2   
Target Milestone: 1.0   
Platform: Other   
OS: Linux   
Latest Commit: Version Fixed/Implemented In:
Sentry Crash Report:
Attachments: Screenshot
Screenshot ABOUT
Screenshot ADD WIDGET
Widget rendering
plasmashell --replace 2>&1 | tee -a log.txt
Screenshot

Description BugCoder 2020-10-28 07:53:59 UTC
SUMMARY
System monitor sensor widget details windows is blank a after upgrade to plasma 5.20

STEPS TO REPRODUCE
1. add System Monitor Widget
2. open System Monitor Widget configuration
3. click on Sensors Details

OBSERVED RESULT
Sensor details window is blank, no options appear

EXPECTED RESULT
Different options to add sensors.


SOFTWARE/OS VERSIONS
Windows: 
macOS: 
Linux/KDE Plasma: Kde Neon 20.04 
(available in About System)
KDE Plasma Version: 5.20 / 5.21
KDE Frameworks Version: 5.75.0
Qt Version: 5.15.0

ADDITIONAL INFORMATION
Comment 1 Nate Graham 2020-10-29 19:21:43 UTC
Can you add a screenshot?
Comment 2 Marcio Merlone 2020-11-03 00:57:25 UTC
Created attachment 132975 [details]
Screenshot
Comment 3 Marcio Merlone 2020-11-03 00:57:57 UTC
Created attachment 132976 [details]
Screenshot ABOUT
Comment 4 Marcio Merlone 2020-11-03 00:58:19 UTC
Created attachment 132977 [details]
Screenshot ADD WIDGET
Comment 5 Marcio Merlone 2020-11-03 00:59:21 UTC
Desired=Unknown/Install/Remove/Purge/Hold
| Status=Not/Inst/Conf-files/Unpacked/halF-conf/Half-inst/trig-aWait/Trig-pend
|/ Err?=(none)/Reinst-required (Status,Err: uppercase=bad)
||/ Nome           Versão                            Arquitectura Descrição
+++-==============-=================================-============-================================================
ii  kded5          5.75.0-0xneon+20.04+focal+build14 amd64        Extensible daemon for providing session services



DISTRIB_ID=neon
DISTRIB_RELEASE=20.04
DISTRIB_CODENAME=focal
DISTRIB_DESCRIPTION="KDE neon User Edition 5.20"
Comment 6 Marcio Merlone 2020-11-03 01:01:01 UTC
(In reply to Marcio Merlnoe from comment #3)
> Created attachment 132976 [details]
> Screenshot ABOUT

As we are here, the link "kde.org" points to "Não foi possível executar o comando especificado. O arquivo ou pasta /usr/lib/x86_64-linux-gnu/qt5/qml/org/kde/kirigami.2/kde.org não existe."
Comment 7 Marcio Merlone 2020-11-03 01:02:21 UTC
Created attachment 132978 [details]
Widget rendering
Comment 8 Christoph Feck 2020-11-09 23:55:21 UTC
New information was added with recent comments; changing status for inspection.
Comment 9 BugCoder 2020-11-19 11:02:02 UTC
After upgrade to 5.20.3 still is blank
Comment 10 Nate Graham 2020-11-19 14:50:35 UTC
Can you run plasmashsll in a terminal window with `plasmashell --replace` and then open the settings window? It should print some errors to the terminal window. The full output would be appreciated.
Comment 11 Marcio Merlone 2020-11-19 20:09:08 UTC
Created attachment 133469 [details]
plasmashell --replace 2>&1 | tee -a log.txt
Comment 12 Marcio Merlone 2020-11-19 20:10:38 UTC
Created attachment 133470 [details]
Screenshot
Comment 13 Nate Graham 2020-11-19 20:35:33 UTC
Thanks. This repeated message certainly seems relevant.

file:///home/marcio/.local/share/plasma/plasmoids/org.kde.networkMonitor/contents/ui/HistoryGraph.qml:41: TypeError: Cannot read property 'height' of null
Comment 14 Nate Graham 2023-09-19 20:21:39 UTC
Hello and thank you again for the bug report! Unfortunately we were not able to address it yet, nor even manage to reproduce the issue ourselves. Can we ask you to please check if this issue is still happening with Plasma 5.27?

If it is, please change the status to REPORTED. Thanks a lot!