Summary: | Keyboard navigation on desktop is broken | ||
---|---|---|---|
Product: | [Plasma] plasmashell | Reporter: | Jacopo Torrini <jactor> |
Component: | Folder | Assignee: | Eike Hein <hein> |
Status: | RESOLVED FIXED | ||
Severity: | major | CC: | kde, kyrimis, mahen, mo78, nate, plasma-bugs, thomas.surrel |
Priority: | VHI | Keywords: | usability |
Version: | 5.14.0 | ||
Target Milestone: | 1.0 | ||
Platform: | Neon | ||
OS: | Linux | ||
Latest Commit: | https://commits.kde.org/plasma-desktop/03b17ac5ec3e04aebe07e69d9240e035fa743c2e | Version Fixed In: | 5.14.1 |
Description
Jacopo Torrini
2018-10-09 15:32:35 UTC
Can confirm, keyboard navigation (arrow keys, all shortcuts) stopped working. *** Bug 399578 has been marked as a duplicate of this bug. *** Eike submitted a patch: https://phabricator.kde.org/D16106 Git commit 480962c3ff93f9d3839a426b9ac053399d03e38d by Eike Hein. Committed on 10/10/2018 at 17:27. Pushed by hein into branch 'Plasma/5.14'. Focus handling fixes Summary: * Fix keyboard nav on the desktop again. * Fix initial focus properly. * Make sure when using arrows after starting Plasma or after clicking into empty space, the first selected item is always 0, not 1 or some random item based on previous activity. * Make sure the view is always scrolled up when (re)opening the popup. Reviewers: broulik Subscribers: plasma-devel Tags: #plasma Differential Revision: https://phabricator.kde.org/D16106 M +6 -0 containments/desktop/package/contents/ui/FolderView.qml M +3 -0 containments/desktop/package/contents/ui/FolderViewLayer.qml M +10 -2 containments/desktop/package/contents/ui/main.qml https://commits.kde.org/plasma-desktop/480962c3ff93f9d3839a426b9ac053399d03e38d *** Bug 399713 has been marked as a duplicate of this bug. *** *** Bug 399779 has been marked as a duplicate of this bug. *** Git commit 03b17ac5ec3e04aebe07e69d9240e035fa743c2e by Eike Hein. Committed on 23/10/2018 at 07:20. Pushed by hein into branch 'Plasma/5.12'. Focus handling fixes Summary: * Fix keyboard nav on the desktop again. * Fix initial focus properly. * Make sure when using arrows after starting Plasma or after clicking into empty space, the first selected item is always 0, not 1 or some random item based on previous activity. * Make sure the view is always scrolled up when (re)opening the popup. Reviewers: broulik Subscribers: plasma-devel Tags: #plasma Differential Revision: https://phabricator.kde.org/D16106 M +7 -2 containments/desktop/package/contents/ui/FolderView.qml M +5 -0 containments/desktop/package/contents/ui/FolderViewLayer.qml M +10 -2 containments/desktop/package/contents/ui/main.qml https://commits.kde.org/plasma-desktop/03b17ac5ec3e04aebe07e69d9240e035fa743c2e |