Summary: | Selecting V4L2 CCD as guider in KSTARS/EKOS doesn't open Guide module | ||
---|---|---|---|
Product: | [Applications] kstars | Reporter: | Niels Looije <nlooije> |
Component: | general | Assignee: | Jasem Mutlaq <mutlaqja> |
Status: | RESOLVED NOT A BUG | ||
Severity: | normal | CC: | nlooije |
Priority: | NOR | ||
Version: | 2.9.5 | ||
Target Milestone: | --- | ||
Platform: | Microsoft Windows | ||
OS: | Microsoft Windows | ||
Latest Commit: | Version Fixed In: | ||
Sentry Crash Report: | |||
Attachments: | connected v4l2 CCD |
Was LX90 connected as well? (In reply to Jasem Mutlaq from comment #1) > Was LX90 connected as well? No it wasn't... didn't realize that was a prerequisite. I had pulled all USB cables except the Guider USB cable to make sure it wasn't a USB problem. It now works. Thx. |
Created attachment 112787 [details] connected v4l2 CCD When i select the V4L2 CCD driver as Guider in the INDI profile and connect to it, the guide module is not opened; see picture guide_module.png. When another driver is chosen, e.g. ccd simulator then the guide module does appear. How do i get the guide module to appear with the V4L2 CCD driver?