Bug 262606

Summary: Powerdevil daemon desn't hibernate when battery goes to critical
Product: [Unmaintained] solid Reporter: Lukáš Karas <lukas.karas>
Component: powermanagement-daemonAssignee: Dario Freddi <drf>
Status: RESOLVED FIXED    
Severity: normal    
Priority: NOR    
Version: unspecified   
Target Milestone: ---   
Platform: Ubuntu   
OS: Linux   
Latest Commit: Version Fixed In:
Sentry Crash Report:
Attachments: powerdevil configuration

Description Lukáš Karas 2011-01-09 00:55:39 UTC
Created attachment 55757 [details]
powerdevil configuration

Version:           unspecified (using KDE 4.5.95) 
OS:                Linux

I have set critical level of battery to 5% and action when this level is reached to "hibernate". When my battery reach this level, PowerDevil show me notification that hibernation will start after 30s. But after that do nothing (some minutes).

When I invoke hibernate action manualy (via. Battery monitor applet), it works well.

Reproducible: Always

Steps to Reproduce:
Set critical level to 5%, action when this level is reached to "hibernate", unplug power cable and wait...

Actual Results:  
After notification do nothing.

Expected Results:  
Should hibernate 30s after notification.
Comment 1 Dario Freddi 2011-01-15 21:49:06 UTC
SVN commit 1214662 by dafre:

BUG: 262606

Actually activate the critical battery timer.

 M  +3 -0      powerdevilcore.cpp  


WebSVN link: http://websvn.kde.org/?view=rev&revision=1214662